IG_ISIS_tag_restore_value
Restore tag value(s) saved by IG_ISIS_tag_save_value.
Declaration:
|
Copy Code
|
AT_ERRCOUNT ACCUAPI IG_ISIS_tag_restore_value(
HISISDRV hDriver,
AT_MODE nTag
);
|
Arguments:
Name |
Type |
Description |
hDriver |
HISISDRV |
The handle to the driver. |
nTag |
AT_MODE |
Specifies the tag to be restored. Specify a value of zero to restore all tags saved by a corresponding IG_ISIS_tag_save_value function. |
Return Value:
Error count.
Supported Raster Image Formats:
This function does not process image pixels.
Remarks:
The IG_ISIS_tag_restore_value function restores the values last saved by a IG_ISIS_tag_save_value call, allowing an application to implement cancel or undo functions in settings dialogs so that previous values can be restored.
Use IG_ISIS_tag_restore_value to restore settings to the value(s) that existed when the application issued the most current IG_ISIS_tag_save_value call. If you do not wish to restore settings, then you must call IG_ISIS_tag_flush_value instead. Each call to IG_ISIS_tag_save_value must have a corresponding call to either IG_ISIS_tag_restore_value or IG_ISIS_tag_flush_value. This is a relatively new requirement, as multiple settings can now be saved in a stack. Previously, only one group of settings could be saved at a time, so only one call to IG_ISIS_tag_restore_value or IG_ISIS_tag_flush_value was required.
The value of nTag should correspond to the value of nTag that was used when the corresponding IG_ISIS_tag_save_value was called. The values are saved in a last-in/first-out stack. By saving the settings of all tags multiple times, it is possible to implement a nested set of settings dialogs, one of which can be cancelled to restore original settings, even after accepting the settings in a previous one. (See IG_ISIS_tag_save_value for a complete example.)
Example:
See the example for IG_ISIS_tag_flush_value.
See Also
IG_ISIS_tag_flush_value