ImageGear Professional v18.2 > API Reference Guide > MD Component API Reference > MD Component Functions Reference > Data Set Functions > MED_DCM_DS_copy_get |
This function allocates a new Element List and copies contents of the Data Set associated with HIGEAR to it.
Copy Code
|
|
---|---|
AT_ERRCOUNT ACCUAPI MED_DCM_DS_copy_get( HIGEAR hIGear, HIGMEDELEMLIST* lphDstList); |
Name | Type | Description |
hIGear | HIGEAR | HIGEAR handle to an image from which the Element List will be copied. |
lphDstList | HIGMEDELEMLIST* | Address of the HIGMEDELEMLIST handle to the Data Element List object. |
Returns the number of ImageGear errors that occurred during the function call.
This function does not process image pixels.
The image must have a DICOM DataSet attached to it. Use MED_DCM_DS_exists to check whether the image contains a DataSet. |
When the copied Element List is no longer necessary, it should be destroyed by calling MED_ElemList_destroy().